Submerged hoses
A hose left in a pool, bucket or laundry sink can siphon dirty water back when pressure drops.
A garden hose sitting in a bucket of weed killer is a cross-connection. So is a boiler fill line without protection. We find these weak points and correct them.
No heat, no hot water or a gas smell? Call any time, day or night.
A cross-connection is any actual or potential link between your drinking water and a source of contamination. Cross-connection control is the set of rules and devices that stop contaminated water from flowing back into the supply. Municipal water systems in BC are required to protect the public supply, and many Metro Vancouver cities run cross-connection control programs that apply to commercial buildings and, increasingly, to homes with irrigation or fire sprinklers.
Where backflow prevention is about the devices, cross-connection control is about finding every place a device is needed in the first place. Inside a home those spots are surprisingly common: laundry sink hoses, water softener and filter drains, hydronic heating fills, hot tub top-ups, submerged hose ends and older toilet fill valves. Able Pro surveys the plumbing, explains the risk of each connection and recommends the simplest correct fix.
Most homeowners have at least one of these and do not know it.
A hose left in a pool, bucket or laundry sink can siphon dirty water back when pressure drops.
Boiler water containing glycol or inhibitors needs a proper backflow device on the make-up line.
Buried sprinkler heads sit in soil and fertilizer, so they must be isolated from house water.
Equipment drain lines must discharge with an air gap, not piped directly into a drain.
Fill points for spas and water features need an air gap or approved assembly.
Hose bibbs without a vacuum breaker are a frequent unprotected connection.
We trace the plumbing from the meter to every fixture and connection point.
Each cross-connection is classed by risk so you know what is urgent and what is minor.
Air gaps, vacuum breakers or testable assemblies, matched to the hazard and local rules.
We install what is needed and give you a list of devices that require ongoing testing.
Boilers and hydronic systems are a top source of home cross-connections, and we service both.
We match protection to the real risk, avoiding both shortcuts and overkill.
You get a simple list of what was found and what was done.
Call (236) 222-2222 or book online at a time that suits you.
Still unsure? Call (236) 222-2222 and talk it through with us.
They are related. A cross-connection is the link between clean water and a contaminant; backflow is the reverse flow that can carry the contaminant through that link. Cross-connection control finds the links, and backflow preventers close them.
An air gap is a physical open space between the end of a water outlet and the flood level of whatever it fills. Because water cannot jump across air, it is the most reliable protection, which is why codes require it for many drain and fill connections.
Requirements vary by municipality. Most residential obligations come into play when you have irrigation, fire sprinklers or similar systems, or during renovations. Check any notice from your city, and we can help you understand it.
Yes. Documented backflow incidents have introduced fertilizers, boiler chemicals and bacteria into drinking water. The risk in one home may be small, but the consequences can affect neighbours on the same main.
Simple fixes such as vacuum breakers and air gaps have no noticeable effect. Testable assemblies cause a small pressure drop, which we account for when choosing and sizing the device.
Book a cross-connection survey online or call (236) 222-2222 to protect your family's water.